Mining - Type 1 Machine Cable

Single Core Tinned Copper Flexible Building Wire, Single Core Flex, Panel Wire, Flexible Cable,
Multi-stranded cable.

image of type 1 machine cable
Australian made, high quality Type 1 Machine Cable.
APPLICATION For interconnection of equipment, e.g. control boxes, motors for mining machines and underground mines. Intended for wiring where further measures need to be taken to protect the cable mechanically when used externally in mining machines.
CONSTRUCTION - CONDUCTOR Tinned annealed copper wire
INSULATION V90-HT Lead-free PVC
COLOURS White numbered cores
TEMPERATURE 0°C to +90°C
VOLTAGE 0.6/1kV
STANDARDS AS1972, AS1125, AS3808

TYPE 1 MACHINE CABLE

BAMBACH NUMBER NOMINAL AREA
mm
STRANDING
No. of Strands/mm
NOMINAL DIAMETER mm CURRENT RATING Amps WEIGHT
Kg/m
14475BK 2 CORE x 1.5mm2 30/0.25 8.6 24 0.092
14463BK 4 CORE x 1.5mm2 30/0.25 10.1 24 0.168
14461BK 6 CORE x 1.5mm2 30.0.25 12.3 24 0.232
47894BKS 30 CORE x 1.5mm² 30/0.25 25.3 24 1.095

TYPE 3 MACHINE CABLE WITH SILICONE CORES

APPLICATION

For interconnection of equipment, e.g. control boxes, motors for mining machines and underground mines. The silicone cores give the cable a longer life in high temperature environments.
CONSTRUCTION - CONDUCTOR Tinned annealed copper wire
INSULATION Silicone Rubber
SCREENING Overall tinned copper braid interwoven with high tensile yarn
SHEATH

Red V90-HT PVC

COLOURS Red, Black, Blue, White
TEMPERATURE 0°C to +90°C
VOLTAGE 0.6/1Kv – not suitable for connection to mains
STANDARDS AS1972, AS1125, AS3808
 
BAMBACH NUMBER NOMINAL AREA
mm
STRANDING
No. of Strands/mm
NOMINAL DIAMETER mm CURRENT RATING Amps WEIGHT
Kg/m